## Go modbus stack
|
|
|
|
### Description
|
|
This package is a go implementation of the modbus protocol.
|
|
It aims to provide a simple-to-use, high-level API to interact with modbus
|
|
devices using native Go types.
|
|
|
|
Both client and server components are available.
|
|
|
|
The client supports the following modes:
|
|
- modbus RTU (serial, over both RS-232 and RS-485),
|
|
- modbus TCP (a.k.a. MBAP),
|
|
- modbus TCP over TLS (a.k.a. MBAPS or Modbus Security),
|
|
- modbus TCP over UDP (a.k.a. MBAP over UDP),
|
|
- modbus RTU over TCP (RTU tunneled in TCP for use with e.g. remote serial
|
|
ports or cheap TCP to serial bridges),
|
|
- modbus RTU over UDP (RTU tunneled in UDP).
|
|
|
|
Please note that UDP transports are not part of the Modbus specification.
|
|
Some devices expect MBAP (modbus TCP) framing in UDP packets while others
|
|
use RTU frames instead. The client support both so if unsure, try with
|
|
both udp:// and rtuoverudp:// schemes.
|
|
|
|
The server supports:
|
|
- modbus TCP (a.k.a. MBAP),
|
|
- modbus TCP over TLS (a.k.a. MBAPS or Modbus Security).
|
|
|
|
A CLI client is available in cmd/modbus-cli.go and can be built with
|
|
```bash
|
|
$ go build -o modbus-cli cmd/modbus-cli.go
|
|
$ ./modbus-cli --help
|
|
```
|
|
|
|
### Getting started
|
|
```bash
|
|
$ go get github.com/simonvetter/modbus
|
|
```
|
|
|
|
### Using the client
|
|
|
|
```golang
|
|
import (
|
|
"github.com/simonvetter/modbus"
|
|
)
|
|
|
|
func main() {
|
|
var client *modbus.ModbusClient
|
|
var err error
|
|
|
|
// for a TCP endpoint
|
|
// (see examples/tls_client.go for TLS usage and options)
|
|
client, err = modbus.NewClient(&modbus.ClientConfiguration{
|
|
URL: "tcp://hostname-or-ip-address:502",
|
|
Timeout: 1 * time.Second,
|
|
})
|
|
// note: use udp:// for modbus TCP over UDP
|
|
|
|
// for an RTU (serial) device/bus
|
|
client, err = modbus.NewClient(&modbus.ClientConfiguration{
|
|
URL: "rtu:///dev/ttyUSB0",
|
|
Speed: 19200, // default
|
|
DataBits: 8, // default, optional
|
|
Parity: modbus.PARITY_NONE, // default, optional
|
|
StopBits: 2, // default if no parity, optional
|
|
Timeout: 300 * time.Millisecond,
|
|
})
|
|
|
|
// for an RTU over TCP device/bus (remote serial port or
|
|
// simple TCP-to-serial bridge)
|
|
client, err = modbus.NewClient(&modbus.ClientConfiguration{
|
|
URL: "rtuovertcp://hostname-or-ip-address:502",
|
|
Speed: 19200, // serial link speed
|
|
Timeout: 1 * time.Second,
|
|
})
|
|
// note: use rtuoverudp:// for modbus RTU over UDP
|
|
|
|
if err != nil {
|
|
// error out if client creation failed
|
|
}
|
|
|
|
// now that the client is created and configured, attempt to connect
|
|
err = client.Open()
|
|
if err != nil {
|
|
// error out if we failed to connect/open the device
|
|
// note: multiple Open() attempts can be made on the same client until
|
|
// the connection succeeds (i.e. err == nil), calling the constructor again
|
|
// is unnecessary.
|
|
// likewise, a client can be opened and closed as many times as needed.
|
|
}
|
|
|
|
// read a single 16-bit holding register at address 100
|
|
var reg16 uint16
|
|
reg16, err = client.ReadRegister(100, modbus.HOLDING_REGISTER)
|
|
if err != nil {
|
|
// error out
|
|
} else {
|
|
// use value
|
|
fmt.Printf("value: %v", reg16) // as unsigned integer
|
|
fmt.Printf("value: %v", int16(reg16)) // as signed integer
|
|
}
|
|
|
|
// read 4 consecutive 16-bit input registers starting at address 100
|
|
var reg16s []uint16
|
|
reg16s, err = client.ReadRegisters(100, 4, modbus.INPUT_REGISTER)
|
|
|
|
// read the same 4 consecutive 16-bit input registers as 2 32-bit integers
|
|
var reg32s []uint32
|
|
reg32s, err = client.ReadUint32s(100, 2, modbus.INPUT_REGISTER)
|
|
|
|
// read the same 4 consecutive 16-bit registers as a single 64-bit integer
|
|
var reg64 uint64
|
|
reg64, err = client.ReadUint64(100, modbus.INPUT_REGISTER)
|
|
|
|
// read the same 4 consecutive 16-bit registers as a slice of bytes
|
|
var regBs []byte
|
|
regBs, err = client.ReadBytes(100, 8, modbus.INPUT_REGISTER)
|
|
|
|
// by default, 16-bit integers are decoded as big-endian and 32/64-bit values as
|
|
// big-endian with the high word first.
|
|
// change the byte/word ordering of subsequent requests to little endian, with
|
|
// the low word first (note that the second argument only affects 32/64-bit values)
|
|
client.SetEncoding(modbus.LITTLE_ENDIAN, modbus.LOW_WORD_FIRST)
|
|
|
|
// read the same 4 consecutive 16-bit input registers as 2 32-bit floats
|
|
var fl32s []float32
|
|
fl32s, err = client.ReadFloat32s(100, 2, modbus.INPUT_REGISTER)
|
|
|
|
// write -200 to 16-bit (holding) register 100, as a signed integer
|
|
var s int16 = -200
|
|
err = client.WriteRegister(100, uint16(s))
|
|
|
|
// Switch to unit ID (a.k.a. slave ID) #4
|
|
client.SetUnitId(4)
|
|
|
|
// write 3 floats to registers 100 to 105
|
|
err = client.WriteFloat32s(100, []float32{
|
|
3.14,
|
|
1.1,
|
|
-783.22,
|
|
})
|
|
|
|
// write 0x0102030405060708 to 16-bit (holding) registers 10 through 13
|
|
// (8 bytes i.e. 4 consecutive modbus registers)
|
|
err = client.WriteBytes(10, []byte{
|
|
0x01, 0x02, 0x03, 0x04,
|
|
0x05, 0x06, 0x07, 0x08,
|
|
})
|
|
|
|
// close the TCP connection/serial port
|
|
client.Close()
|
|
}
|
|
```
|
|
### Using the server component
|
|
See:
|
|
* [examples/tcp_server.go](examples/tcp_server.go) for a modbus TCP example
|
|
* [examples/tls_server.go](examples/tls_server.go) for TLS and Modbus Security features
|
|
|
|
### Supported function codes, golang object types and endianness/word ordering
|
|
Function codes:
|
|
* Read coils (0x01)
|
|
* Read discrete inputs (0x02)
|
|
* Read holding registers (0x03)
|
|
* Read input registers (0x04)
|
|
* Write single coil (0x05)
|
|
* Write single register (0x06)
|
|
* Write multiple coils (0x0f)
|
|
* Write multiple registers (0x10)
|
|
|
|
Go object types:
|
|
* Booleans (coils and discrete inputs)
|
|
* Bytes (input and holding registers)
|
|
* Signed/Unisgned 16-bit integers (input and holding registers)
|
|
* Signed/Unsigned 32-bit integers (input and holding registers)
|
|
* 32-bit floating point numbers (input and holding registers)
|
|
* Signed/Unsigned 64-bit integers (input and holding registers)
|
|
* 64-bit floating point numbers (input and holding registers)
|
|
|
|
Byte encoding/endianness/word ordering:
|
|
* Little and Big endian for byte slices and 16-bit integers
|
|
* Little and Big endian, with and without word swap for 32 and 64-bit
|
|
integers and floating point numbers.
|
|
|
|
### Logging ###
|
|
Both client and server objects will log to stdout by default.
|
|
This behavior can be overriden by passing a log.Logger object
|
|
through the Logger property of ClientConfiguration/ServerConfiguration.
|
|
|
|
### TODO (in no particular order)
|
|
* Add RTU (serial) support to the server
|
|
* Add more tests
|
|
* Add diagnostics register support
|
|
* Add fifo register support
|
|
* Add file register support
|
|
|
|
### Dependencies
|
|
* [github.com/goburrow/serial](https://github.com/goburrow/serial) for access to the serial port (thanks!)
|
|
|
|
### License
|
|
MIT.
|